Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis

Product Details
Customization: Available
Customized: Customized
Certification: CE, Cfs LVD ISO9001 RoHS
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 5 foreign trading staff(s) and 2 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
to see all verified strength labels (26)
  • Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
  • Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
  • Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
  • Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
  • Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
  • Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
Find Similar Products

Basic Info.

Model NO.
BMD-A3
Measurement Parameters
T Value, Z Value
Radiation-Free
Safer Than X-Rays
Report Function
Automatically Generates Diagnostic Reports and Sup
Built-in Database
Contains Reference Data for a Variety of Populatio
Measuring Position
Shin Bone/Radius
Transport Package
Wooden Case/ Carton
Trademark
PIN YUAN
Origin
China
HS Code
9018129900

Product Description

Low Investment High-usage
Small limitation High benefit
Measurement parts: Radius and Tibia English menu and Color Printer report
WHO international compatibility. It measuring the people between the age of 0 and 120.(Children and Adult)
 
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis

Main Function Bone Densitometry is to measure the bone density or bone strength of the People's radius and tibia. It is for Preventing osteoporosis.
It is an economic solution for evaluating the risk of osteoporotic fracture. Its high accuracy assists in the first diagnosis of osteoporosis monitoring bone changes. It provides fast, convenient and easy-to-use informations on bone quality and fracture risk.

Application: This portable model is the best choice for hospital outgoing examination, hospital wards, Mobile Inspection, Physical Examination Vehicle, Pharmaceutical factory, Pharmacy and Health Care Products promotion.

 
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis

Application Range:  Our Ultrasound Bone Densitometry always used for Maternal and Child Health Centers, Geriatric Hospital, Sanatorium, Rehabilitation Hospital, Bone Injury Hospital, Physical Examination Center, Health Center, Community Hospital, Pharmaceutical factory,   Pharmacy and Health Care Products Promotion.
The Department of the General Hospital, Such as
Pediatric Department,
Gynecology and Obstetrics Department,
Orthopedics Department,  
Geriatrics Department,  
Physical Examination Department,
Rehabilitation department  
Physical Examination Department
Endocrinology Department

 
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
Portable ultrasound bone densitometry BMD-A3 is for testing bone density.  It can be used for diagnosing diseases, as well as for disease screening and physical examination of healthy people. Ultrasound bone densitometer is cheaper than DEXA  bone densitometer , simple to operate, no radiation, high accuracy, less investment. A bone mineral density test, sometimes just called a bone density test, detects whether you have osteoporosis.
 

When you have the osteoporosis, your bones get weak and thin. They become more likely to break. Bone and joint pain and fractures caused by osteoporosis are common clinical diseases, such as  deformation of the lumbar and back vertebrae, Disc disease, vertebral body fracture,cervical spondylosis, limb joint and bone pain, lumbar spine, femoral neck, radius fracture and so on. Therefore, bone mineral density examination is very necessary for the diagnosis and treatment of osteoporosis and its complications.
 
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis


Ultrasound Bone Densitometry have low investment and benefit.
The advantages as following:
  1. Low Investment
  2. High-usage
  3. Small limitation
  4. Fast return, no consumables
  5. High benefit
  6. Measurement parts: Radius and Tibia.
  7. The probe adopts American DuPont technology
  • The measurement process is simple and fast
  • High measurement speed, short measurement time
  • High Measurement Accuracy
  • Good Measurement Reproducibility 
  • it with different countries clinical database, including: European, American, Asian, Chinese,
  • WHO international compatibility. It measuring the people between the age of 0 and 120.(Children and Adult)
  • English menu and Color Printer report
  • CE Certificate, ISO Certificate, CFDA Certificate, ROHS, LVD, EMC-Electro Magnetic Compatibility
 
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis

 Main Feature:  
  • Portable model, easy to move
  • Precise and Artistic Mould Manufactured
  • Full dry technology, Makes Diagnostic More Convenient.
  • Measurement parts: Radius and Tibia.
  • The measurement process is simple and fast
  • High measurement speed, short measurement time
  • High Measurement Accuracy
  • Good Measurement Reproducibility 
  • The particular correction system to correct system error effectively.
  • it with different countries clinical database, including: European, American, Asian, Chinese,
  • WHO international compatibility. It measuring the people between the age of 0 and 120.(Children and Adult)
  • English menu and Color Printer report
  • CE Certificate, ISO Certificate, CFDA Certificate, ROHS, LVD, EMC-Electro Magnetic Compatibility
Technical Specifications
 Large Scale Integrated circuit
Multi - layer circuit board design
High shielding Multi-point Signal Contact Mode
Precise Mould Manufactured   
 Famous Brand Embedded Industrial Control Computer
Special Analysis System Based on Different Countries People

 
Bone Density testing results

Bone Density testing results will be in the form of two scores:
  T score: This compares your bone density with a healthy, young adult of your gender. The score indicates if your bone density is normal, below normal, or at the levels that indicate osteoporosis.
Here's what the T score means:
-1 and above: Your bone density is normal
-1 to -2.5: Your bone density is low, and it may lead to osteoporosis
-2.5 and above: You have osteoporosis
Z score: This allows you to compare how much bone mass you have compared with other people of your age, gender, and size.
A Z score below -2.0 means that you have less bone mass than someone your age and that it could be caused by something other than aging.
Portable Ultrasonic Bone Mineral Density Detector Bmd-A3 Bone Mineral Density Detector for Adults/Children with Osteoporosis

Configuration: 
1. BMD-A3 Ultrasound Bone Densitometer Main Unit
2. 1.20MHz Probe        
3. Famous Brand Embedded Industrial Control Computer
4. BMD-A3 Intelligent Analysis System
5. Calibrating Module (Perspex sample)
6. Disinfectant Coupling Agent

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier