Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor

Product Details
Customization: Available
Customized: Customized
Certification: CE, Cfs LVD ISO9001 RoHS
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 5 foreign trading staff(s) and 2 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
to see all verified strength labels (26)
  • Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
  • Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
  • Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
  • Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
  • Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
Find Similar Products

Basic Info.

Model NO.
LUD-V1
Scale
Large
Test Type
Support a Variety of Tests, Fvc, Fev1, Mvv, etc
Measurement Accuracy
High Accuracy of Flow and Capacity
Data Storage
Can Store a Large Number of Test Results
Result Analysis
Automatic Analysis and Report Generation
Portability
Lightweight Design, Easy to Carry
Transport Package
Wooden Case/ Carton
Trademark
PIN YUAN
Origin
China
HS Code
9018129900

Product Description

Measurement method differential pressure flow test method
Sensor High precision double differential pressure flow sensor
Flow measurement range 0L/s~±14L/s
Frequency response no more than 0.25L/s or 12%
Service life 8 years
Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor

PinYuan LUD-V1 portable pulmonary function tester specification

The pulmonary function tester we developed and produced use the most advanced differential pressure flow sensor to obtain the measured results,  through  three measurement methods (slow vital capacity (SVC), forced vital capacity (FVC), and voluntary ventilation (MVV)) to get the user's expiratory flow signal , then calculated and evaluated to provide scientific basis for early screening and diagnosis of respiratory diseases such as chronic obstructive pulmonary disease (COPD), emphysema, asthma, etc.  This measurement method is more accurate and efficient. More practical.

 
Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
Product Parameters
1. Measurement method: differential pressure flow test method
2. Sensor: High precision double differential pressure flow sensor
3. Flow measurement range: 0L/s ~ ±14L/s
4. Flow measurement error: The maximum allowable flow error in the measurement range should be: ±10L/min (±0.17L/s) or ±5% of the reading
5. Volume measurement range: 0-8 L volume measurement error: ±3% or ±0.050L, whichever is the maximum
6. Airflow resistance: The airflow resistance within the test range should not exceed 0.35KPa/ (L/s)
7. Frequency response: no more than 0.25L/s or 12%
8. Linearity: the difference of the average error of two adjacent test flows does not exceed 5% of the two test flows, and the test flow change does not exceed 0.17L/S or 5% of the reading
9. Pulmonary function measurement: forced vital capacity (FVC), slow vital capacity (SVC), and voluntary ventilation (MVV) can be measured.
10. Lung function measurements were guided by animation.
11,Measurement parameters:FVC,FEV0.5,FEV1,FEV3,FEV1/FVC,PEF,MEF75,MEF50,MEF25,MMF, OI,FIVC,PIF,FIV1;VC,TV,ERV,IRV,IC,VC/HT;MVV,RR,MVV/BSA,TV,BSA .
12. Volume-flow velocity curve and time-volume curve were generated according to the pulmonary function measurement results.
13. Unique filter and mouth design, more tightness, prevent air leakage during measurement.
14. It has the function of COPD assessment and ventilation defect assessment.
15. System software functions: instrument zero and calibration function, doctor management system, history review system, medical record review function, user file management function.
16. Display: ≥14.1 inch, high-definition color display.
17 Built-in industrial control host structure, more stable performance.
18. Logitech wireless keyboard and mouse operation, more convenient to use.
19. Portable horizontal structure, exquisite and beautiful.
20. Service life: 8 years.
21. Operating system: WIN7 32 bit /64 bit, WIN10 64 bit compatible.
22. Power input: voltage AC220V, Electric current 0.75A, electric power <=60VA.
23. Dimensions: Depth 226mm× width 400mm× height 353mm, Weight: <=8kg.

 
Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
After-Sales Service
The manufacturer provides one year warranty.
When providing permanent maintenance service outside the warranty period, only materials and maintenance fees will be charged, and labor fees will not be charged.
The manufacturer provides 2 hours immediate response, 48 hours to solve the fault service.

 
Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
Lung Function Detector Lud-V1 Bidirectional Differential Pressure Flow Sensor
Service: Jinqiao Zhigu Industrial Park, No.26 Sanhuan East Road, Xuzhou Economic and Technological Development Zone, Jiangsu Province

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier