Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health

Product Details
Customization: Available
Customized: Customized
Certification: CE, Cfs LVD ISO9001 RoHS
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 5 foreign trading staff(s) and 2 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
to see all verified strength labels (26)
  • Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
  • Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
  • Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
  • Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
  • Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
Find Similar Products

Basic Info.

Model NO.
ADS-6000A
Scale
Large
Application
Upper or Lower Limbs
Measurement Parameters
Pwv, Abi, Blood Pressure, etc.
Portability
The Body Is Light and Easy to Carry
User Interface
Intuitive Operation, Simplify The Process
Non-Invasive
No Need to Puncture Blood Vessels
Transport Package
Wooden Case/ Carton
Trademark
PIN YUAN
Origin
China
HS Code
9018129900

Product Description

Measurement site upper arm, lower limb ankle
Measurement accuracy ±0.4kPa(±3mmHg)
Measurement range 0kPa ~ 34.7kPa(0mmHg ~ 260mmHg)
Rated power 115VA voltage 220V
The width range of lower limb measurement 16cm-33cm
Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
Arteriosclerosis is a non-inflammatory disease of the artery, which can make the arterial wall thickening, hardening, loss of elasticity, and stenosis of the lumen. Arteriosclerosis is a vascular disease that occurs with age. It usually occurs in adolescence and becomes worse in the middle and old age. There were more males than females. In recent years, this disease has gradually increased in our country, and has become one of the main causes of sudden death and other diseases.

Atherosclerosis is the most common and serious type of arteriosclerosis. Coronary atherosclerosis can cause insufficient blood supply to the myocardium, resulting in angina pectoris, myocardial infarction, arrhythmia, and even sudden death. Cerebral arteriosclerosis, can cause cerebral insufficiency, vertigo, headache, cerebral ischemia. Thrombosis in cerebral arteries or cerebral stroke caused by rupture of small aneurysms caused by arteriosclerosis may result in loss of consciousness, hemiplegia, aphasia and other serious consequences. Atherosclerosis of the lower limbs may cause intermittent claudication, loss of pulse of the dorsalis pedis artery, and in severe cases, ischemic necrosis of the limb ends.

 
Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health

The most common causes of arteriosclerosis are hyperlipidemia, hypertension, diabetes, and the patient's own lifestyle. Relevant data show that the intake of greasy food and high-cholesterol food directly leads to hypercholesterolemia, and hypercholesterolemia is just one of the risk factors for atherosclerosis and cardiovascular disease.

For most patients with arteriosclerosis, early detection, early detection and reasonable intervention can effectively reduce the morbidity, disability rate and mortality of cardiovascular and cerebrovascular diseases.

ADS-6000A Technical parameters of Arteriosclerosis Detector

ADS-6000A Arteriosclerosis Detector is an arterial stiffness and obstruction degree detector with complete independent intellectual property rights. The instrument uses synchronous compression to measure the blood pressure of the limbs noninvasively, simultaneously records and analyzes the pulse wave shape of the limbs, uses waveform analysis technology to extract the characteristic information that characterizes the blood vessel elasticity, calculates a number of indexes including ankle brachial index (ABI), brachial ankle artery pulse wave velocity (baPWV), and performs automatic analysis and comprehensive evaluation through the database data, to evaluate the health status of cardiovascular system and the degree of lower extremity artery obstruction, and provide comprehensive objective basis for early diagnosis of arteriosclerosis and early screening of cardiovascular and cerebrovascular diseases.

 
Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
Technical features:
1,Accurately assess the elasticity of the great arteries and the degree of lower extremity artery obstruction
The ankle-brachial index measured by synchronous compression of all limbs reduces the influence of blood pressure variability, and the results are more accurate, baPWV+ABI measurement is more reliable in assessing large artery elasticity.
2,Simple, fast, non-invasive measurement method, easy to complete the index measurement
The use of high sensitivity pulse wave sensor non-invasive inspection, will not bring any physical harm to the user. The instrument is simple to operate, the detection time is short, and the index measurement is completed quickly.
3,The network function can easily support online transmission and remote management of data.
4,Scientific theoretical basis and accurate test data
Independent intellectual property rights, years of medical data acuumulation, and passed  clinical verification.
5,ABI was detected by synchronous compression of the limbs
Due to the constant fluctuation of blood pressure, only ABI values measured by simultaneous compression of the extremities are more meaningful. The 2006 ACC/AHA guidelines for the management of peripheral artery disease recommend the use of simultaneous measurement of blood pressure on all limbs to obtain ABI values.
6,Risk assessment of cardiovascular disease
The unique cardiovascular disease risk assessment system objectively assesses the 10-years risk of ischemic cardiovascular disease.
7,Network interaction and data upload function
The data can be batchly imported from the remote server, and the test data can be uploaded to the remote server at any time, and can be integrated with the health management system as needed.
8,Accurate blood pressure measurement: the quality and performance of the internationally renowned blood pressure monitoring module are more reliable and the measurement results are more accurate.

 
Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health
Arteriosclerosis Detector Equipment Ads-6000A Noninvasive Detection of Vascular Health

Technical parameters:
1,The blood pressure of the extremities was measured synchronously by the oscillometric method.
2,Measurement site: limbs: upper arm, lower limb ankle.
3,Arm circumference measurement range: 20-38cm.
4,The width range of lower limb measurement: 16cm-33cm.
5,Rated power: 115VA voltage 220V.
6,Performance requirements of blood pressure measurement:
Measurement range: 0kPa ~ 34.7kPa(0mmHg ~ 260mmHg);
Measurement accuracy: ±0.4kPa(±3mmHg);
Repeatability: measured under static continuous low pressure, the difference between the repeated measured readings at each point within the scale range is not greater than 0.533 kPa(4mmHg).
7,12.1 inch HD LCD screen, branded industrial control computer system.
8,Measurement parameters: baPWV (brachial-ankle pulse wave velocity), ABI (ankle brachial index), BAI (brachial-ankle index), HR(heart rhythm), PVR (pulse volume recording), systolic blood pressure SBP(limbs), diastolic blood pressure DBP(limbs), mean blood pressure MAP(limbs), pulse pressure PP(limbs).
9,Portable structural design, easy to move.
10,Equipped with lithium battery, capacity of 5200mAH.
11,Lithium battery working time up to 3 hours.



 