Ultrasound Bone Density Detector for Medical Detection of Osteoporosis

Product Details
Customization: Available
Customized: Customized
Certification: CE, Cfs LVD ISO9001 RoHS
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 5 foreign trading staff(s) and 2 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
to see all verified strength labels (26)
  • Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
  • Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
  • Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
  • Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
  • Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
Find Similar Products

Basic Info.

Model NO.
BMD-A7
Measuring Position
Shin Bone/Radius
Built-in Database
Contains Reference Data for a V
Report Function
Automatically Generates Diagnosti
Radiation-Free
Safer Than X-Rays
Measurement Parameters
T Value, Z Value
Transport Package
Wooden Case/ Carton
Trademark
PIN YUAN
Origin
China
HS Code
9018129900

Product Description

Measurement parts radius and Tibia
Measurement parameters Speed of sound (SOS)
Measurement  Accuracy ≤0.15%
Measurement Reproducibility ≤0.15%
Measurement  mode double emission and double receiving
database connectors With HIS , DICOM, database connectors
 
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
Main Function Bone Densitometry is to measure the bone density or bone strength of the People's radius and tibia. It is for Preventing osteoporosis.
It is an economic solution for evaluating the risk of osteoporotic fracture. Its high accuracy assists in the first diagnosis of osteoporosis monitoring bone changes. It provides fast, convenient and easy-to-use informations on bone quality and fracture risk.

Application:
Our BMD have extensive application: it used for Maternal and Child Health Centers, Geriatric Hospital, Sanatorium, Rehabilitation Hospital, Bone Injury Hospital, Physical Examination Center, Health Center, Community Hospital, Pharmaceutical factory,   Pharmacy and Health Care Products

The Department of the General Hospital, Such as Pediatric Department, Gynecology and Obstetrics Department, Orthopedics Department,  Geriatrics Department,  Physical Examination, Department,  Rehabilitation Department 

 
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis

Application Range:  Our Ultrasound Bone Densitometry always used for Maternal and Child Health Centers, Geriatric Hospital, Sanatorium, Rehabilitation Hospital, Bone Injury Hospital, Physical Examination Center, Health Center, Community Hospital, Pharmaceutical factory,   Pharmacy and Health Care Products Promotion.

The Department of the General Hospital, Such as
Pediatric Department,
Gynecology and Obstetrics Department,
Orthopedics Department,  
Geriatrics Department,  
Physical Examination Department,
Rehabilitation department  
Physical Examination Department
Endocrinology Department

 
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis

Trolley ultrasound bone densitometry BMD-A7 is for testing bone density.  It can be used for diagnosing diseases, as well as for disease screening and physical examination of healthy people. Ultrasound bone densitometer is cheaper than DEXA  bone densitometer , simple to operate, no radiation, high accuracy, less investment. A bone mineral density test, sometimes just called a bone density test, detects whether you have osteoporosis.
When you have the osteoporosis, your bones get weak and thin. They become more likely to break. Bone and joint pain and fractures caused by osteoporosis are common clinical diseases, such as  deformation of the lumbar and back vertebrae, Disc disease, vertebral body fracture,cervical spondylosis, limb joint and bone pain, lumbar spine, femoral neck, radius fracture and so on. Therefore, bone mineral density examination is very necessary for the diagnosis and treatment of osteoporosis and its complications.

Ultrasound Bone Densitometry have low investment and benefit.
The advantages as following:
  1. Low Investment
  2. High-usage
  3. Small limitation
  4. Fast return, no consumables
  5. High benefit
  6. Measurement parts: Radius and Tibia.
  7. The probe adopts American DuPont technology
  • The measurement process is simple and fast
  • High measurement speed, short measurement time
  • High Measurement Accuracy
  • Good Measurement Reproducibility 
  • it with different countries clinical database, including: European, American, Asian, Chinese,
  • WHO international compatibility. It measuring the people between the age of 0 and 120.(Children and Adult)
  • English menu and Color Printer report
  • CE Certificate, ISO Certificate, CFDA Certificate, ROHS, LVD, EMC-Electro Magnetic Compatibility
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis

Main Feature:  
  • Trolley model
  • Precise and Artistic Mould Manufactured
  • Full dry technology, Makes Diagnostic More Convenient.
  • Measurement parts: Radius and Tibia.
  • The measurement process is simple and fast
  • High measurement speed, short measurement time
  • High Measurement Accuracy
  • Good Measurement Reproducibility 
  • The particular correction system to correct system error effectively.
  • it with different countries clinical database, including: European, American, Asian, Chinese,
  • WHO international compatibility. It measuring the people between the age of 0 and 120.(Children and Adult)
  • English menu and Color Printer report
  • CE Certificate, ISO Certificate, CFDA Certificate, ROHS, LVD, EMC-Electro Magnetic Compatibility

Technical Specifications
Large Scale Integrated circuit
Multi - layer circuit board design
High shielding multipoint signal contact mode
Precise brushed metal mould manufactured   
Special analysis system based on different countries people

Technical features: 
1.Using the full dry technology,  makes diagnostic more convenient.
2.The probe adopt the Technology of the United States DuPont, makes the probe to receive higher sensitivity and better reception.
3.the better ultrasonic frequency on the measuring position, with better penetrability, more effective signal
4.use the ultrasonic axial conduction technology, double emission and double receiving, it can provide more effective data
5.With innovative algorithm, effectively remove clutter and jamming signal, to get the valid data.
6.With a special correction system, to correct the system error effectively, get more accurate measurement results.
7. Multipoint access mode with high shield and mold manufacturing, to ensure the lossless transmission of the ultrasonic signals.
8. It with multi countries clinical database, including: European, American, Asian, Chinese, WHO international compatibility. It measuring the people between the age of 0 and 100
9. English menu
10. The first one pass EMC test
11. CE certificate.
12. ISO Certificate.

 
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis

Performance parameter:
  1. Measurement parts: radius and Tibia
  2.  Measurement  mode: double emission and double receiving
  3. Measurement parameters:  Speed of sound (SOS)
  4. Analysis Data: T- Score, Z-Score, Age percent[%], Adult percent[%], BQI (Bone quality Index ), PAB[Year]  (physiological age of bone), EOA[Year] (Expected Osteoporosis age), RRF(Relative Fracture Risk).
  5. Measurement  Accuracy : ≤0.15%
  6. Measurement Reproducibility:  ≤0.15%
  7. Measurement  time:  Three-cycles adult measurement <15 seconds, Three-cycle Children measurement  <3 seconds
  8. Probe frequency : 1.20MHz
  9. Date analysis :  it adopt a special intelligent real -time data analysis system, it selects the adult or child databases according to the age automatically .
  10.  Temperature control: Perspex sample with temperature instructions
  11.  Probe measurement navigation:  this equipment display the Axial angle ,  the Horizontal Angle , the Direction Angle between the probe and the bone plane, it display the change of the real-time angle data.  It is easy to correct the measure angle quickly, improving the measure speed , improving the data Accuracy.
  12.  Probe crystal indication: it display the working condition for the four crystal of the probe, and the signal strength for the ultrasonic reception.
  13. Daily Calibration:  automatic calibrating after power on.
  14. All the people of the world. It measuring the people between the age Of 0 and 100,(Children: 0-12 years old, Teenagers: 12-20 years old, Adults:20-80 years old, The Elderly 80-100 yeas old,  only need to input the age and recognizing automatically .
  15. Temperature display calibration block:  the calibration with pure copper and Perspex,  the calibrator display current temperature and standard SOS. The equipment leave the factory with Perspex sample.
  16. repot mode: color
  17.  Report format: supply A4, 16K ,B5 and more size report
  18. Bone densitometer main unit: Drawing Aluminum mould manufacturing, it is exquisite and beautiful
  19. With HIS , DICOM, database connectors
  20. Bone densitometer probe connector: multipoint access mode with high shield and mold manufacturing, to ensure the lossless transmission of the ultrasonic signals.
  21. Computer Main Unit: the original Dell Rack business Computer. Signal processing and analysis are fast and accurate.
  22. Computer configuration:  original Dell business configuration: G3240, dual core, 4G memory, 500G hard disk, original Dell recorder., wireless mouse. (optional )
  23. Computer Monitor: 20' color HD color LED monitor. (optional )
  24. Trolley(optional)
  25. Fluid Protection: main unit waterproof level IPX0, probe waterproof level IPX7
  26. External medical special power supply, power>60W
  27.  Connect to the internet and provide remote services.
Ultrasound Bone Density Detector for Medical Detection of Osteoporosis
Bone Density testing results will be in the form of two scores:
T score: This compares your bone density with a healthy, young adult of your gender. The score indicates if your bone density is normal, below normal, or at the levels that indicate osteoporosis.
Here's what the T score means:
-1 and above: Your bone density is normal
-1 to -2.5: Your bone density is low, and it may lead to osteoporosis
-2.5 and above: You have osteoporosis
Z score: This allows you to compare how much bone mass you have compared with other people of your age, gender, and size.
A Z score below -2.0 means that you have less bone mass than someone your age and that it could be caused by something other than aging.

Configuration:
1. Ultrasound Bone Densitometer Trolley Main unit (inner Dell business Computer with i3 CPU    )
2. 1.20MHz Probe   
3. BMD-A5 Intelligent Analysis System                                4.Canon Color InkJet Printer G1800
5. Dell 19.5 inch Color LED Mornitor
6. Calibrating Module( Perspex sample)  7.Disinfectant Coupling Agent
Package Size:
One Carton
Size(cm): 59cm×43cm×39cm
G.W.12 Kgs
 N.W: 10 Kgs

One Wooden Case
Size(cm): 73cm×62cm×98cm
G.W.48 Kgs
 N.W: 40 Kgs

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier