Low Investment |
High-usage |
Small limitation |
High benefit |
Measurement parts: Radius and Tibia |
English menu and Color Printer report |
WHO international compatibility. It measuring the people between the age of 0 and 120.(Children and Adult) |
Main Function Bone Densitometry is to measure the bone density or bone strength of the People's radius and tibia. It is for Preventing osteoporosis.
It is an economic solution for evaluating the risk of osteoporotic fracture. Its high accuracy assists in the first diagnosis of osteoporosis monitoring bone changes. It provides fast, convenient and easy-to-use informations on bone quality and fracture risk.
Application: This portable model is the best choice for hospital outgoing examination, hospital wards, Mobile Inspection, Physical Examination Vehicle, Pharmaceutical factory, Pharmacy and Health Care Products promotion.
Application Range: Our Ultrasound Bone Densitometry always used for Maternal and Child Health Centers, Geriatric Hospital, Sanatorium, Rehabilitation Hospital, Bone Injury Hospital, Physical Examination Center, Health Center, Community Hospital, Pharmaceutical factory, Pharmacy and Health Care Products Promotion.
The Department of the General Hospital, Such as
Pediatric Department,
Gynecology and Obstetrics Department,
Orthopedics Department,
Geriatrics Department,
Physical Examination Department,
Rehabilitation department
Physical Examination Department
Endocrinology Department
When you have the osteoporosis, your bones get weak and thin. They become more likely to break. Bone and joint pain and fractures caused by osteoporosis are common clinical diseases, such as deformation of the lumbar and back vertebrae, Disc disease, vertebral body fracture,cervical spondylosis, limb joint and bone pain, lumbar spine, femoral neck, radius fracture and so on. Therefore, bone mineral density examination is very necessary for the diagnosis and treatment of osteoporosis and its complications.
Ultrasound Bone Densitometry have low investment and benefit.
The advantages as following:
- Low Investment
- High-usage
- Small limitation
- Fast return, no consumables
- High benefit
- Measurement parts: Radius and Tibia.
- The probe adopts American DuPont technology
- The measurement process is simple and fast
- High measurement speed, short measurement time
- High Measurement Accuracy
- Good Measurement Reproducibility
- it with different countries clinical database, including: European, American, Asian, Chinese,
- WHO international compatibility. It measuring the people between the age of 0 and 120.(Children and Adult)
- English menu and Color Printer report
- CE Certificate, ISO Certificate, CFDA Certificate, ROHS, LVD, EMC-Electro Magnetic Compatibility
Main Feature:
1. Using the full dry technology, makes diagnostic more convenient.
2. The probe adopt the Technology of the United States DuPont, makes the probe to receive higher sensitivity and better reception.
3. the better ultrasonic frequency on the measuring position, with better penetrability, more effective signal
4. Two probes: 1.20MHz Ultrasound Probe and 125MHz ultrasound probe are available
5. use the ultrasonic axial conduction technology, double emission and double receiving, it can provide more effective data
6. With innovative algorithm, effectively remove clutter and jamming signal, to get the valid data.
7. With a special correction system, to correct the system error effectively, get more accurate measurement results.
8. multipoint access mode with high shield and mold manufacturing, to ensure the lossless transmission of the ultrasonic signals.
9. it with multi race clinical database, including: European, American, Asian, Chinese, WHO international compatibility. It measuring the people between the age of 0 and 120.
9. English manual, Chinese (Traditional) manual
10. the first one pass EMC test
11. CE certificate.
12. ROHS certificate
13. LVD certificate.
12. ISO 13485, ISO 9001.
13. CFS Certificate.
14. CFDA Certificate
Bone Density testing results
Bone Density testing results will be in the form of two scores:
T score: This compares your bone density with a healthy, young adult of your gender. The score indicates if your bone density is normal, below normal, or at the levels that indicate osteoporosis.
Here's what the T score means:
-1 and above: Your bone density is normal
-1 to -2.5: Your bone density is low, and it may lead to osteoporosis
-2.5 and above: You have osteoporosis
Z score: This allows you to compare how much bone mass you have compared with other people of your age, gender, and size.
A Z score below -2.0 means that you have less bone mass than someone your age and that it could be caused by something other than aging.
Performance parameter:
1. Measurement parts: radius and Tibia
2. Measurement mode: double emission and double receiving
3. Measurement parameters: Speed of sound (SOS)
4. Analysis Data: T- Score, Z-Score, Age percent[%], Adult percent[%], BQI (Bone quality Index ), PAB[Year] (physiological age of bone), EOA[Year] (Expected Osteoporosis age), RRF(Relative Fracture Risk). BMI , SOS
It has the functions of T value trend chart and Z value trend chart.
5. Measurement Accuracy : ≤0.25%
6. Measurement Reproducibility: ≤0.25%
7. Measurement time:
Three Cycles adults measuring time <15 seconds
Three Cycle Children measuring time < 3seconds
8. Probe frequency : 1.20MHz ,DuPont Technology
9. Automatic determination of measurement results
10. The text template has an automatic addressing function, which is convenient for report editing
11. It has a report statistics function
12. It has a medical record name correction function
13. It has reexamination function
14. It has a one-button Chinese-English conversion function
15. It has a fast and slow measuring function
16. Date analysis : it adopt a special intelligent real -time data analysis system, it selects the adult or child databases according to the age automatically .
17. Temperature control: Perspex sample with temperature instructions
18. Probe measurement navigation: this equipment display the Axial angle , the Horizontal Angle , the Direction Angle between the probe and the bone plane, it display the change of the real-time angle data. It is easy to correct the measure angle quickly, improving the measure speed , improving the data Accuracy.
19. Probe crystal indication: it display the working condition for the four crystal of the probe, and the signal strength for the ultrasonic reception.
20. Daily Calibration: automatic calibrating after power on.
21. All the people of the world. It measuring the people between the age Of 0 and 120,(Children: 0-12 years old, Teenagers: 12-20 years old, Adults:20-80 years old, The Elderly 80-120 yeas old, only need to input the age and recognizing automatically .
22. Temperature display calibration block: the calibration with pure copper and Perspex, the calibrator display current temperature and standard SOS. The equipment leave the factory with Perspex sample.
23. report mode: color report or report which printer by thermal printer
24. Report format: supply A4, 16K , B5 and more size report
25. Printer: two type to choose, one is Color inkjet Printer, another is Build in Thermal Printer
26. Portable model, with probe holder
27. Computer configuration: QUAD CPU , RAM 4G , 128G Solid State Drive, wireless mouse
28. Bone densitometer probe connector: multipoint access mode with high shield and mold manufacturing, to ensure the lossless transmission of the ultrasonic signals.
29. External medical special power supply, power>60W
30. Connect to the internet and provide remote services.
31. Monitor: 14.0' color HD color LED monitor.
32. Fluid Protection: main unit waterproof level IP20, probe waterproof level IPX7
33. Main unit weight< 5 kgs, easy to carry
34. Added anti-interference ability
35. Environmental test complies with: GB/T14710-2009 requirements
36. Electromagnetic compatibility test complies with: YY0505-2012 requirements
37. Industry standard complies with: YY/T0774-2019 requirements
38. Electromagnetic compatibility test compliance complies with: YY9706.102-2