Measurement parts |
radius and Tibia |
Measurement parameters |
Speed of sound (SOS) |
Measurement Accuracy |
≤0.15% |
Measurement Reproducibility |
≤0.15% |
Measurement mode |
double emission and double receiving |
database connectors |
With HIS , DICOM, database connectors |
Main Function Bone Densitometry is to measure the bone density or bone strength of the People's radius and tibia. It is for Preventing osteoporosis.
It is an economic solution for evaluating the risk of osteoporotic fracture. Its high accuracy assists in the first diagnosis of osteoporosis monitoring bone changes. It provides fast, convenient and easy-to-use informations on bone quality and fracture risk.
Application:
Our BMD have extensive application: it used for Maternal and Child Health Centers, Geriatric Hospital, Sanatorium, Rehabilitation Hospital, Bone Injury Hospital, Physical Examination Center, Health Center, Community Hospital, Pharmaceutical factory, Pharmacy and Health Care Products
The Department of the General Hospital, Such as Pediatric Department, Gynecology and Obstetrics Department, Orthopedics Department, Geriatrics Department, Physical Examination, Department, Rehabilitation Department
Application Range: Our Ultrasound Bone Densitometry always used for Maternal and Child Health Centers, Geriatric Hospital, Sanatorium, Rehabilitation Hospital, Bone Injury Hospital, Physical Examination Center, Health Center, Community Hospital, Pharmaceutical factory, Pharmacy and Health Care Products Promotion.
The Department of the General Hospital, Such as
Pediatric Department,
Gynecology and Obstetrics Department,
Orthopedics Department,
Geriatrics Department,
Physical Examination Department,
Rehabilitation department
Physical Examination Department
Endocrinology Department
Trolley ultrasound bone densitometry BMD-A7 is for testing bone density. It can be used for diagnosing diseases, as well as for disease screening and physical examination of healthy people. Ultrasound bone densitometer is cheaper than DEXA bone densitometer , simple to operate, no radiation, high accuracy, less investment. A bone mineral density test, sometimes just called a bone density test, detects whether you have osteoporosis.
When you have the osteoporosis, your bones get weak and thin. They become more likely to break. Bone and joint pain and fractures caused by osteoporosis are common clinical diseases, such as deformation of the lumbar and back vertebrae, Disc disease, vertebral body fracture,cervical spondylosis, limb joint and bone pain, lumbar spine, femoral neck, radius fracture and so on. Therefore, bone mineral density examination is very necessary for the diagnosis and treatment of osteoporosis and its complications.
Ultrasound Bone Densitometry have low investment and benefit.
The advantages as following:
- Low Investment
- High-usage
- Small limitation
- Fast return, no consumables
- High benefit
- Measurement parts: Radius and Tibia.
- The probe adopts American DuPont technology
- The measurement process is simple and fast
- High measurement speed, short measurement time
- High Measurement Accuracy
- Good Measurement Reproducibility
- it with different countries clinical database, including: European, American, Asian, Chinese,
- WHO international compatibility. It measuring the people between the age of 0 and 120.(Children and Adult)
- English menu and Color Printer report
- CE Certificate, ISO Certificate, CFDA Certificate, ROHS, LVD, EMC-Electro Magnetic Compatibility
- Trolley model
- Precise and Artistic Mould Manufactured
- Full dry technology, Makes Diagnostic More Convenient.
- Measurement parts: Radius and Tibia.
- The measurement process is simple and fast
- High measurement speed, short measurement time
- High Measurement Accuracy
- Good Measurement Reproducibility
- The particular correction system to correct system error effectively.
- it with different countries clinical database, including: European, American, Asian, Chinese,
- WHO international compatibility. It measuring the people between the age of 0 and 120.(Children and Adult)
- English menu and Color Printer report
- CE Certificate, ISO Certificate, CFDA Certificate, ROHS, LVD, EMC-Electro Magnetic Compatibility
Technical Specifications
Large Scale Integrated circuit
Multi - layer circuit board design
High shielding multipoint signal contact mode
Precise brushed metal mould manufactured
Special analysis system based on different countries people
Technical features:
1.Using the full dry technology, makes diagnostic more convenient.
2.The probe adopt the Technology of the United States DuPont, makes the probe to receive higher sensitivity and better reception.
3.the better ultrasonic frequency on the measuring position, with better penetrability, more effective signal
4.use the ultrasonic axial conduction technology, double emission and double receiving, it can provide more effective data
5.With innovative algorithm, effectively remove clutter and jamming signal, to get the valid data.
6.With a special correction system, to correct the system error effectively, get more accurate measurement results.
7. Multipoint access mode with high shield and mold manufacturing, to ensure the lossless transmission of the ultrasonic signals.
8. It with multi countries clinical database, including: European, American, Asian, Chinese, WHO international compatibility. It measuring the people between the age of 0 and 100
9. English menu
10. The first one pass EMC test
11. CE certificate.
12. ISO Certificate.
Performance parameter:
- Measurement parts: radius and Tibia
- Measurement mode: double emission and double receiving
- Measurement parameters: Speed of sound (SOS)
- Analysis Data: T- Score, Z-Score, Age percent[%], Adult percent[%], BQI (Bone quality Index ), PAB[Year] (physiological age of bone), EOA[Year] (Expected Osteoporosis age), RRF(Relative Fracture Risk).
- Measurement Accuracy : ≤0.15%
- Measurement Reproducibility: ≤0.15%
- Measurement time: Three-cycles adult measurement <15 seconds, Three-cycle Children measurement <3 seconds
- Probe frequency : 1.20MHz
- Date analysis : it adopt a special intelligent real -time data analysis system, it selects the adult or child databases according to the age automatically .
- Temperature control: Perspex sample with temperature instructions
- Probe measurement navigation: this equipment display the Axial angle , the Horizontal Angle , the Direction Angle between the probe and the bone plane, it display the change of the real-time angle data. It is easy to correct the measure angle quickly, improving the measure speed , improving the data Accuracy.
- Probe crystal indication: it display the working condition for the four crystal of the probe, and the signal strength for the ultrasonic reception.
- Daily Calibration: automatic calibrating after power on.
- All the people of the world. It measuring the people between the age Of 0 and 100,(Children: 0-12 years old, Teenagers: 12-20 years old, Adults:20-80 years old, The Elderly 80-100 yeas old, only need to input the age and recognizing automatically .
- Temperature display calibration block: the calibration with pure copper and Perspex, the calibrator display current temperature and standard SOS. The equipment leave the factory with Perspex sample.
- repot mode: color
- Report format: supply A4, 16K ,B5 and more size report
- Bone densitometer main unit: Drawing Aluminum mould manufacturing, it is exquisite and beautiful
- With HIS , DICOM, database connectors
- Bone densitometer probe connector: multipoint access mode with high shield and mold manufacturing, to ensure the lossless transmission of the ultrasonic signals.
- Computer Main Unit: the original Dell Rack business Computer. Signal processing and analysis are fast and accurate.
- Computer configuration: original Dell business configuration: G3240, dual core, 4G memory, 500G hard disk, original Dell recorder., wireless mouse. (optional )
- Computer Monitor: 20' color HD color LED monitor. (optional )
- Trolley(optional)
- Fluid Protection: main unit waterproof level IPX0, probe waterproof level IPX7
- External medical special power supply, power>60W
- Connect to the internet and provide remote services.
Bone Density testing results will be in the form of two scores:
T score: This compares your bone density with a healthy, young adult of your gender. The score indicates if your bone density is normal, below normal, or at the levels that indicate osteoporosis.
Here's what the T score means:
-1 and above: Your bone density is normal
-1 to -2.5: Your bone density is low, and it may lead to osteoporosis
-2.5 and above: You have osteoporosis
Z score: This allows you to compare how much bone mass you have compared with other people of your age, gender, and size.
A Z score below -2.0 means that you have less bone mass than someone your age and that it could be caused by something other than aging.
Configuration:
1. Ultrasound Bone Densitometer Trolley Main unit (inner Dell business Computer with i3 CPU )
2. 1.20MHz Probe
3. BMD-A5 Intelligent Analysis System 4.Canon Color InkJet Printer G1800
5. Dell 19.5 inch Color LED Mornitor
6. Calibrating Module( Perspex sample) 7.Disinfectant Coupling Agent
Package Size:
One Carton
Size(cm): 59cm×43cm×39cm
G.W.12 Kgs
N.W: 10 Kgs
One Wooden Case
Size(cm): 73cm×62cm×98cm
G.W.48 Kgs
N.W: 40 Kgs